DT 8908D High Accuracy Multimeter Tester Portable Manual Range Burn Proof Industrial LCD Voltmeter










Descrizione
Feature: 1. [LCD LARGE SCREEN] Adopts a 6000 digit digital display screen, it is equipped with a bar graph, a backlight mode, and supports analog bar and digital dual display. 2. [WIDE SCOPE OF APPLICATION] Its AC variable frequency measurement can be used for motors, non contact power measurement (NCV) and drive measurement (VFD). 3. [IP67 PROTECTION DESIGN] It is fully dustproof and waterproof, allowing you to easily measure electrical parameters in a variety of complex environments. 4. [SAFE AND RELIABLE] With overload protection function, it uses high quality explosion proof tube, which can effectively protect the safety of measuring personnel. 5. [HIGH PRACTICALITY] Small size, it is lightweight and portable, can measure AC and DC voltages up to 1000V, and can be easily used in various situations. Specification: Item Type: Digital Multimeter Model: DT 8908D Material: ABS Battery: 4x1.5V AAA Battery (Battery Not Included) Purpose: It is suitable for electrical parameter measurement. Display: 6000 Digit LCD Display AC Response: True Effective Value Measurement Fuse: 630mA 250V Fuse; 20A 250V Fuse Polarity: Automatically Distinguish The Polarity, ( ) Negative Over Range: OL Display Low Voltage Prompt: Low Battery Symbol Prompt Automatic Shutdown: 15 Minutes of No Operation Measuring Speed: 3 Times Per Second Operating Environment: 0 celsius to 40 celsius (4 Fahrenheit to 104 Fahrenheit ) Relative Humidity <70percent RH Storage Temperature: 10 celsius to 50 celsius (14 Fahrenheit to 122 Fahrenheit ) Relative Humidity <80percent Maximum Indoor Use Height: 2000m DC Voltage 600.0mV 0.1mV + 0.5percent of rdg+ 8 dgts 6.000V 1mV 60.00V 10mV + 0.7percent of rdg+ 5 dgts 600.0V 100mV + 0.7percent of rdg+ 8 dgts 1000V 1V AC Voltage 6.000V 1mV + 1.2percent of rdg+ 5 dgts 60.00V 10mV 600.0V 100mV 1000V 1V DC Current 60.00uA 0.01uA + 1.0percent of rdg+ 5 dgts 60.00mA 10uA 600.0mA 100uA + 1.2percent of rdg+ 8 dgts 20.00A 10mA + 2.0percent of rdg+ 10 dgts AC Current 60.00mA 10uA + 1.0percent of rdg+ 5 dgts 600.0mA 100uA + 1.2percent of rdg+ 8 dgts 20.00A 10mA + 2.0percent of rdg+ 10 dgts Resistance 600.0 Ohm 0.1 Ohm + 1.0percent of rdg+ 5 dgts 6.000k Ohm 1 Ohm + 1.5percent of rdg+ 5 dgts 60.00k Ohm 10 Ohm 600.0k Ohm 100 Ohm 6.000M Ohm 1k Ohm + 2.5percent of rdg+ 8 dgts 60.00M Ohm 10k Ohm Capacitance 60.00nF 10pF + 2.5percent of rdg+ 8 dgts 600.0nF 0.1nF + 3.0percent of rdg+ 8 dgts 6.000microfarad 1nF 60.00microfarad 0.01microfarad + 3.5percent of rdg+ 10 dgts 600.0microfarad 0.1microfarad 6.000mF 1microfarad 60.00mF 10microfarad + 5.0percent of rdg+ 10 dgts 100.0mF 100microfarad How to Use: .DC Voltage Measurement: Note: Do not perform measurement at the moment when the power is turned on or off, as high voltage may damage the meter. 1. Place the function dial at the VDC (range: 600mV, 6V, 60V, 600V, 1000V) position; 2. Insert the black test into the negative COM port and the red test into the positive V port; 3. Touch the tip of the test to the test object to ensure that the electrode is correct (red connects the positive electrode, and black connects the negative electrode); 4. Read the voltage value on the display. When it is greater than 30V, the LCD will display a high voltage danger symbol. When it is greater than 1000V, the buzzer will sound. The red light is always on. If the electrode is reversed, a minus sign will be displayed before the value. AC Voltage Measurement: Warning: Please observe all safety precautions when measuring on wires with wires. Note: Do not perform measurement at the moment when the power is turned on or off, as high voltage may damage the meter. 1. Set the function dial to VAC HZ (range: 6V, 60V, 600V, 1000V); 2. Insert the black test into the negative COM port and the red test into the positive port; 3. Touch the tip of the test to the test object; 4. Read the voltage value on the display. When it is greater than 30V, the LCD will display a high voltage danger symbol. When it is greater than 1000V, the buzzer will sound and the red light will be on; 5. Short press the MODE button to enter the AC voltage frequency measurement mode, the measurement range is 45Hz 1KHz. DC Current Measurement: Note: The measurement time cannot exceed 10 seconds under the condition of 20A, otherwise the meter or test s may be damaged. During the measurement, if the current cannot be estimated, the measurement should be started from the high range, and if necessary, the low range should be selected. 1. Insert the black test into the negative COM port; 2. Measure the current below 600mA DC, set the function dial to DC 60uA or mA (range: 60mA, 600mA), and insert the red test into the mA port; 3. When measuring DC 20A, set the function dial to the 20A gear and insert the red test into the 20A port; 4. Disconnect the power supply of the tested circuit, touch the black test to the negative pole of the tested circuit, and the red test to the positive pole of the tested circuit; 5. Turn on the power supply; 6. Read the current value on the display. When it is greater than 10A, the buzzer will sound and the red light will stay on. AC Current Measurement: Warning: To prevent electric shock, do not measure on a circuit with a voltage exceeding 250V. Note: The measurement time cannot exceed 10 seconds under the condition of 20A, otherwise the meter or test s may be damaged. During the measurement, if the current cannot be estimated, the measurement should be started from the high range, and if necessary, the low range should be selected. 1. Insert the black test into the negative COM port; 2. When measuring 600mA, put the function keyboard in the AC 60mA, 600mA gear position, and insert the red test into the mA port; 3. When measuring 20A, place the function keyboard in the 20A position and insert the red test into the 20A port; 4. Disconnect the power supply of the tested circuit, touch the black test to the negative pole of the tested circuit, and the red test to the positive pole of the tested circuit; 5. Turn on the power supply; 6. When the current value read on the display is greater than 10A, the buzzer will sound and the red light will stay on; 7. Short press the MODE tank to enter the AC current frequency measurement mode, the measurement range is 45Hz 1KHz. Package List: 1 x Digital Multimeter (Battery Not Included)2 x Test s1 x K Type Temperature Probe1 x Manual




























